Waldorf Pulse Manual do Utilizador Página 68

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 78
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 67
68
User’s Manual Pulse • PulsePlus
Polyphony Parameter Dump
Byte No Value Parameter Description/Range
0 $F0 Exclusive Status SysEx transfer start
1 $3E Manufacturer ID Waldorf Electronics GmbH
2 $0B Model ID Pulse ID
3 0...126 Device ID Equivalent to the global parameter device ID
4 $0A Function Code Dump type, polyphony parameter dump
5 0...11 Number of Pulses Total number of Pulses-1 in stack
6 0...11 Identification Number Identification number of Pulse-1 in stack
7 $F7 EOX End of SysEx message
Program Dump Request
Byte No Value Parameter Description/Range
0 $F0 Exclusive Status SysEx transfer start
1 $3E Manufacturer ID Waldorf Electronics GmbH
2 $0B Model ID Pulse ID
3 0...126 Device ID Equivalent to the global parameter device ID
4 $40 Function Code Dump type program dump request
5 0...99 Program No P.1 ... P.99 / P.rn
6 $F7 EOX End of SysEx message
Program Bulk Dump Request
Byte No Value Parameter Description/Range
0 $F0 Exclusive Status SysEx transfer start
1 $3E Manufacturer ID Waldorf Electronics GmbH
2 $0B Model ID Pulse ID
3 0...126 Device ID Equivalent to the global parameter device ID
4 $41 Function Code Dump type program bulk dump request
5 0...99 Program No P.1 ... P.99 / P.rn
6 $F7 EOX End of SysEx message
Global Parameter Dump Request
Byte No Value Parameter Description/Range
0 $F0 Exclusive Status SysEx transfer start
1 $3E Manufacturer ID Waldorf Electronics GmbH
2 $0B Model ID Pulse ID
3 0...126 Device ID Equivalent to the global parameter device ID
4 $48 Function Code Dump type global parameter dump request
5 $F7 EOX End of SysEx message
Vista de página 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 77 78

Comentários a estes Manuais

Sem comentários